Life cycle assessment of solar-powered green ammonia in Lebanon versus imported grey ammonia: firming options, grid-share thresholds and resource trade-offs
- Rasha Alkassem1 & Mohammed Abdalghafoor2
- DOI: 10.5281/zenodo.23857365
- ISA Journal of Engineering and Technology (ISAJET)
Green ammonia is widely
presented as a low-carbon substitute for fossil-based fertiliser, but most life
cycle assessments assume a steady supply of renewable electricity that a
solar-powered plant does not have. This study asks whether ammonia produced in
Lebanon from solar power can outperform the grey ammonia that the country
effectively imports, mainly from Egypt as urea, once the intermittency of solar
supply is modelled explicitly. A cradle-to-gate attributional life cycle
assessment following ISO 14040/44 was built for 1 kg of anhydrous ammonia
delivered to the Bekaa valley. Grey ammonia from Egyptian natural-gas steam
reforming, including upstream gas emissions and shipping, was compared with
electrolytic ammonia supplied by Bekaa photovoltaics under five configurations:
grid only, PV with grid backup, PV with hydrogen storage and winter grid
top-up, islanded PV with batteries, and islanded PV with hydrogen storage and a
flexible Haber–Bosch loop. Solar supply was simulated hour by hour on
representative days, and equipment was sized for each configuration. Climate
change, water consumption and scarcity, and mineral resource depletion were
assessed, with scenario, sensitivity and 10,000-run Monte Carlo analyses. Grey
ammonia emitted 2.78 kg CO2e/kg NH3 (90% interval 2.34–3.17). The islanded
configurations emitted 0.28 (hydrogen storage) and 0.47 (batteries) kg CO2e/kg
NH3, and the hybrid with winter grid top-up 0.94, all lower than grey in every
Monte Carlo run. In contrast, PV with grid backup emitted 3.82 and grid-only
electrolysis 6.58 kg CO2e/kg NH3, because Lebanese electricity, 60% of it from
diesel generators, carries 0.626 kg CO2e/kWh. Green ammonia breaks even with
grey at a grid share of about 40% (90% interval 30–59%), whereas PV without
storage cannot reduce the grid share below about 51%. The climate gain comes at
the cost of 12–23 times higher mineral depletion, driven by silver in PV
modules and copper in batteries, and 2.5–3.7 times higher water consumption.
Storage, not solar capacity, therefore decides whether Lebanese green ammonia
is low-carbon, and support schemes should require islanded operation or
verified hourly matching.
Keywords: green ammonia; Haber–Bosch; solar
photovoltaics; hydrogen storage; life cycle assessment; Lebanon.